According to current Code for design of concrete structures and Technical specification for concretestructures of tall building the principle of design of the reinforced concrete shear wall and the column for section of vertical axis is basic consistent
but having a dissimilarity of section shape
the actual apply calculate method has differentiation.In this paper we study the difference of simply calculation on section of vertical axis of shear wall and column
and put forward coincident condition when applying formula.