浏览全部资源
扫码关注微信
新疆大学电气工程学院
Published:2021
移动端阅览
[1]刘江山,李凤婷,解超,等.直流馈入对工频变化量距离保护影响分析及改进[J].新疆大学学报(自然科学版)(中英文),2021,38(06):753-763.
[1]刘江山,李凤婷,解超,等.直流馈入对工频变化量距离保护影响分析及改进[J].新疆大学学报(自然科学版)(中英文),2021,38(06):753-763. DOI: 10.13568/j.cnki.651094.651316.2020.12.29.0003.
DOI:10.13568/j.cnki.651094.651316.2020.12.29.0003.
为研究直流馈入对工频变化量距离保护的影响
建立了直流系统等值工频变化量阻抗模型
基于不同故障程度下直流控制策略的切换
分析了直流系统等值工频变化量阻抗的变化特性及其对工频变化量距离保护的影响.在过渡电阻较大的情况下
直流系统等值工频变化量阻抗呈容性
会造成工频变化量距离保护正方向保护范围减小.基于此
提出了工频变化量阻抗继电器与全阻抗继电器配合的改进方法
有效改善了由于直流馈入造成保护拒动的问题.最后
基于PSCAD/EMTDC的仿真结果验证了理论分析的正确性和改进措施的有效性.
In order to research the influence of DC feed on power-frequency variation distance protection
the equivalent power-frequency variation impedance model of the DC system is established. Based on the switching of HVDC control strategies under different fault levels
the change characteristics of the equivalent power-frequency variation impedance of the DC system and its influence on the power-frequency variation distance protection are analyzed. It is concluded that when the fault resistance is large
the equivalent power-frequency variation impedance of the DC system is capacitive
which will cause the protection range of the power-frequency variation distance protection to be reduced in the positive direction. Based on this
an improved method for the coordination of power-frequency variation impedance relays and impedance relays is proposed
which can solve the problem of the reduction of the protection range in the positive direction caused by DC feed. Finally
the simulation results based on PSCAD/EMTDC verify the correctness of the theoretical analysis and the effectiveness of the improvement measures.
尹纯亚,李凤婷,张增强,等.直流闭锁引发多馈出直流系统换相失败分析[J].新疆大学学报(自然科学版), 2019, 36(2):138-145.YIN C Y, LI F T, ZHANG Z Q, et al. Commutation failure analysis of multi-outfeed HVDC system caused by DC blocking[J].Journal of Xinjiang University(Natural Science Edition), 2019, 36(2):138-145.(in Chinese)
鲁月华,樊艳芳,罗瑞.适用于交直流混联系统的时域全量故障模型判别纵联保护方案[J].电力系统保护与控制, 2020, 48(19):81-88.LU Y H, FAN Y F, LUO R. Principle of active distribution network pilot protection based on time domain model identification[J].Power System Protection and Control, 2020, 48(19):81-88.(in Chinese)
王锐铭,李凤婷.一种改善直流系统恢复特性的低压限流环节优化方法[J].新疆大学学报(自然科学版)(中英文), 2021, 38(2):235-241+250.WANG R M, LI F T. An optimization method of VDCOL to improve the recovery characteristics of DC system[J]. Journal of Xinjiang University(Natural Science Edition in Chinese and English), 2021, 38(2):235-241+250.(in Chinese)
董新洲,汤涌,卜广全,等.大型交直流混联电网安全运行面临的问题与挑战[J].中国电机工程学报, 2019, 39(11):3107-3118.DONG X Z, TANG Y, BU G Q, et al. Confronting problem and challenge of large scale AC-DC hybrid power grid operation[J].Proceedings of the CSEE, 2019, 39(11):3107-3118.(in Chinese)
索南加乐,张健康,焦在滨,等.交直流混联电网交流系统故障特征分析[J].高电压技术, 2010, 36(6):1461-1467.SUONAN J L, ZHANG J K, JIAO Z B, et al. AC fault characteristic analysis of AC-DC hybrid transmission grid[J]. High Voltage Engineering, 2010, 36(6):1461-1467.(in Chinese)
李永丽,杨子荷,宋金钊,等. HVDC馈入及其换相失败对交流电网选相元件的影响分析[J].电网技术, 2020, 44(5):1825-1834.LI Y L, YANG Z H, SONG J Z, et al. Influence analysis of HVDC and commutation failure on AC phase selector[J]. Power System Technology, 2020, 44(5):1825-1834.(in Chinese)
申洪明,黄少锋,费彬. HVDC换相失败暂态特性及其对差动保护的影响分析和对策[J].电力自动化设备, 2015, 35(4):109-114+120.SHEN H M, HUANG S F, FEI B. Transient characteristic of HVDC system during commutation failure, its effect on differential protection and countermeasures[J]. Electric Power Automation Equipment, 2015, 35(4):109-114+120.(in Chinese)
申洪明,黄少锋,费彬.交直流互联系统对距离保护动作特性的影响分析及对策[J].电力系统自动化, 2015, 39(11):58-63+82.SHEN H M, HUANG S F, FEI B. Effect analysis of AC-DC interconnected network on distance protection performance and countermeasures[J]. Automation of Electric Power Systems, 2015, 39(11):58-63+82.(in Chinese)
刘俊磊,王钢,李海锋,等. HVDC系统换相失败对交流电网继电保护影响的机理分析[J].中国电机工程学报, 2013, 33(19):111-118.LIU J L, WANG G, LI H F, et al. Mechanism analysis of HVDC commutation failure influence on AC power network relay protection[J]. Proceedings of the CSEE, 2013, 33(19):111-118.(in Chinese)
杨子荷,李永丽,宋金钊,等.直流馈入下交流系统故障特性分析及故障分量电流差动保护改进[J].电力自动化设备, 2019,39(9):3-10.YANG Z H, LI Y L, SONG J Z, et al. Fault characteristics analysis and fault component current differential protection improvement of AC system with infeed DC[J]. Electric Power Automation Equipment, 2019, 39(9):3-10.(in Chinese)
李海锋,张璞,王钢,等.直流馈入下的工频变化量方向纵联保护动作特性分析(一)直流系统等值工频变化量阻抗模型[J].电力系统自动化, 2009, 33(9):41-46.LI H F, ZHANG P, WANG G, et al. Performance of directional protection based on variation of power-frequency components in HVDC-AC interconnected system, part one:DC-system equivalent impedance of power-frequency component variation[J].Automation of Electric Power Systems, 2009, 33(9):41-46.(in Chinese)
张健康,索南加乐,孙成,等.基于参数识别的纵联保护在交直流混联电网中的应用研究[J].电力系统保护与控制, 2012, 40(24):34-39.ZHANG J K, SUONAN J L, SUN C, et al. Application of pilot protection based on parameter identification in AC-DC hybrid grid[J]. Power System Protection and Control, 2012, 40(24):34-39.(in Chinese)
费彬,黄少锋,申洪明.交直流互联系统对距离保护的影响分析及对策[J].电力自动化设备, 2015, 35(8):15-21.FEI B, HUANG S F, SHEN H M. Impact of AC-DC interconnected system on distance protection and countermeasure[J]. Electric Power Automation Equipment, 2015, 35(8):15-21.(in Chinese)
罗瑞,樊艳芳.交直流系统连锁故障引发功率倒向方向保护策略[J].电力自动化设备, 2019, 39(12):189-197.LUO R, FAN Y F. Directional protection strategy of power inversion caused by chain fault of AC-DC hybrid system[J]. Electric Power Automation Equipment, 2019, 39(12):189-197.(in Chinese)
索南加乐,何方明,焦在滨,等.工频变化量距离元件特性的研究[J].中国电机工程学报, 2010, 30(28):59-65.SUONAN J L, HE F M, JIAO Z B, et al. Research on the characteristics of distance element based on the power-frequency voltage and current variation[J]. Proceedings of the CSEE, 2010, 30(28):59-65.(in Chinese)
徐妍,陆广香,徐晓敏,等.关于工频变化量距离保护可靠性的研究[J].电力系统保护与控制, 2015, 43(20):51-57.XU Y, LU G X, XU X M, et al. Research on the reliability of the distance protection using power-frequency variable components[J].Power System Protection and Control, 2015, 43(20):51-57.(in Chinese)
徐岩,林旭涛,赵亮,等.大型风电场对工频故障分量距离保护影响的研究[J].电力系统保护与控制, 2013, 41(10):118-125.XU Y, LIN X T, ZHAO L, et al. Research on impact of large wind farms on distance relay using power fault component[J]. Power System Protection and Control, 2013, 41(10):118-125.(in Chinese)
雷霖,赖真良,朱家龙,等.工频变化量距离继电器耐受过渡电阻性能分析[J].电力系统保护与控制, 2017, 45(17):26-33.LEI L, LAI Z L, ZHU J L, et al. Performance analysis of endure transition resistance of distance relay based on the power-frequency voltage and current variation[J]. Power System Protection and Control, 2017, 45(17):26-33.(in Chinese)
张健康,索南加乐,何方明,等.交直流混联电网工频变化量距离保护动作特性分析[J].电力系统自动化, 2013, 37(4):98-103.ZHANG J K, SUONAN J L, HE F M, et al. Performance of distance protection based on fault component applied to AC-DC hybrid gird[J]. Automation of Electric Power Systems, 2013, 37(4):98-103.(in Chinese)
蔡东晓,李海锋,祝新驰,等.送出直流对工频变化量元件的影响机理分析[J].电力系统保护与控制, 2019, 47(9):1-9.CAI D X, LI H F, ZHU X C, et al. Mechanism analysis of the impact of DC system on power-frequency variation protections[J].Power System Protection and Control, 2019, 47(9):1-9.(in Chinese)
0
Views
291
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621